RPCF series reactive power automatic compensation controller

General description

RPCF series reactive power automatic compensation controller,based on 16-digit micro processor,adopt fourier progression decompose arithmetic,to get power fundamental wave data,the controller specially used for compensating reactive power in the power system with harmonic wave source.All components are of surface mounting technology,regurgitant solder,multi-stage inspection,these will make all RPCF controllers work steadily and reliably.RPCFC type has RS485 port,standard protocol.It can be used as network meter.

Function features

- On basis of fundamental wave reactive power,calculate the reactive power to be switched on,it can avoid  witching
  shock of any forms,it can accurately display the power factor of system with harmonic wave.
- High measurement accuracy,wide display scope.
- Real time display the distortion rates of voltage and current.
- Total 12 kinds of coding output can be chosen.
- 16 circuits of output at maximum.
- Human friendly interface,convenient operation.
- Various control setting can be adjusted digitally,directly and easily.
- Automatic and manual operations,two modes provided.
- Over voltage and absent voltage protection provided.
- Protection against superscale of harmonic wave voltage.
- Data not lost even if power shun down.
- Current signal input resistance ≤0.01Ω.
- Communication function(MODBUS-RTU RS485) provided.
- Compensating power factor able to be adjusted:0.70 lag~0.7 forward.

Main technical parameter

- Rated working voltage:380V,220V,110V±10%.
- Rated working current:5A.
- Rated working frequency:45-65Hz.
- Power factor displayed:lag 0.001-forward 0.001.
- Measured reactive power:0-9999Kvar.
- Measured active power:0-9999KW.
- Absent voltage protection:AC300V or AC 180V.
- Capacity of output contact:AC 220V 7A.
- Sensitivity:20mA.
- Display mode:4 digit red LED.
- Total consumption:10VA.
- Outline size:144mm*144mm or 122mm*122mm or 170mm*110mm.
- Opening hole size:138mm*138mm or 113mm*113mm or 162mm*102mm.
- Mounting mode:plug-in mounting by inverse thread screw or rail way mounting.
- Value setting scope:
  a.Auto/Manual Automatic/Manual operation
  b.Power factor 0.70ind-0.70cap.
  c.Switching delay 2-200 S
  d.Capacitor discharging duration 0-480 s.
  e.Over voltage Line voltage 400-450V(phase voltage:230-265V).
  f.Distortion rate 0.1-30.0%.
  g.CT transformation ratio 50-4000/5.
  h.C1 capacity 0.1-100.0Kvar.
  i.Output code Pr-01-12.
  j.Output circuits 1-16 circuits.
  k.Communication address 1-255.
  l.Communication speed 4800,9600,19200,115200.


                  


Power Semiconductors
Automation Electrics
Circuit Breakers
Control & Protection Electrics
LED Lighting
Relays
Interface Components
Switches and Switchgears


Home | Site Map | Switches and Switchgears | Interface Components | Relays | LED Lighting | Control & Protection Electrics
Recommend Products: Residual Current Operated Breaker (CB,Semko CE approval) | GVTA series three phase AC switching module (50A to 500A) | Phase control thyristor upto 6500V for SVC and high voltage soft starter | Integrated high-power energy-saving lamps, 125W & 145W. | LED Street Light (56W, IP65, Rectangular Beam)

Copyright 2007 Greegoo All Right Reserved