LW26 Series rotary switches
Introduction
| - - - - - - |
LW26 series rotary switches represent the most advanced rotary switches. We currently have six models,current rating up to 160A, suitable for wide variety of applications; LW26 series rotary switches are suitable for: on-off of an electrical circuit, change-over of electrical circuits,motor switch, instrument switch, and main switch; LW26 series rotary switches comply with: GB 14048.3, GB 14048.5, and IEC 60947-5-1; LW26 series rotary switches have six current ratings: 20A, 25A, 32A, 63A, 125A, and 160A. LW26-20 and LW26-25 has the fingerproof terminals, which offered an extra advantage; LW26 series rotary switches have wide variety of applications, they are ideal substitution for LW2, LW5, LW6, LW8, LW12, LW15, HZ5, HZ10, HZ12, and other rotary switches and cam switches; LW26 series rotary switch has two derivatives: LW26GS Pak-lock type switch (63A and below) and LW26S Key-lock type switch (32A and below), which could be installed in instruments to prevent the equipments from mis- operations. |
Working conditions
- Ambient temperature Do Not exceed 40℃, and the average temperature,measured over a period of 24 hours,Do Not exceed 35;
- Ambient temperature Do Not less than -5℃;
- Should Not be installed above 2000m above sea level;
- A clean environment was required.
Designation
Use as control switches
|
|
1: Rotary switch (Cam switch);
2: Product code;
3: Rated thermal current;
4: Code of the degree of rotation;
5: Character code;
6: Code for contact of the switch;
7: Number of layers.
Re: Character code represent the rotating type, for instance, we have limited movement, spring return and limited movement with spring return.
Use as control switches
|
|
1: Rotary switch (Cam switch);
2: Product code;
3: Rated thermal current;
4: Motor Rating (3 phase AC);
5: Usage Code: 1 Q for start and run;
2 N for reversing;
3 S for 2 speed;
4 SN for 2 speed and reversing;
6: Number of layers.
Re: switches in this category normally rotate at 60 . And the SN normally rotate at 45.
Use as control switches
|
|
1: Rotary switch (Cam switch);
2: Product code;
3: Rated thermal current;
4: Number poles: 2 poles, 3poles, and 4poles.
Re: switches in this category normally rotate at 60.
Classification
- Classified by utilization:
(1)Cange-over switch;
(2)Motor switch;
(3)Control switch;
- Classified by operation:
(1)Limited movement;
(2)Spring return;
(3)Limited movement with spring geturn;
- Classified by contact system:
(1)Switches with limited movement could have 12 layers in maximum (for 32A and below), and for 63A and
above could have 8 layers in maximum;
(2)Switches with spring return could have 3 layers in maximum;
(3)Motor switches could have 6 layers in maximum.
- Diagram for the operation and position of handle.
| Operation angle | Code | Position of handle | |||||||||
| 60 Rotation | 90 Rotation | ||||||||||
| Spring return | A | ||||||||||
| B | |||||||||||
| Limited moven ment | C | 0° | 60° | 0° | 90° | ||||||
| D | 60° | 0° | 60° | 90° | 0° | 90° | |||||
| E | 90° | 30° | 30° | 90° | 90° | 0° | 90° | 180° | |||
| F | 90° | 30° | 30° | 90° | 150° | ||||||
| G | 150° | 90° | 30° | 30° | 90° | 150° | |||||
| H | |||||||||||
| I | |||||||||||
| J | |||||||||||
| K | |||||||||||
| L | |||||||||||
| M | |||||||||||
| N | 30° | 30° | |||||||||
| P | 90° | 0° | |||||||||
| Limited movement with spring retum | Z | 60° | 0° | 60° | |||||||
| 90° | 60° | 0° | 60° | 90° | |||||||
| 120° | 60° | 0° | 60° | 120° | |||||||
Escutcheon plate
|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
| Description | Escutcheon plate | Type of handle | ||||||||||||
| M0 | M1 | M1B | M2 | M2B | M3 | R | F | I | B | H | L | P | K | |
| LW26-10 | ![]() |
![]() |
||||||||||||
| LW26X-10 | ![]() |
![]() |
||||||||||||
| LW26-20 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26X-20 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-25 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-32 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| LW26-32F | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| LW26-63 | ![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |
||||
| LW26-125 | ![]() |
![]() |
![]() |
![]() |
||||||||||
| LW26-160 | ![]() |
![]() |
![]() |
![]() |
||||||||||
| Description | Rotating angle | Maximum number of layers | |||||
| 30 | 45 | 60 | 90 | 12 | 10 | 8 | |
| LW26-10 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26X-10 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-20 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26X-20 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-25 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-32 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-32F | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-63 | ![]() |
![]() |
![]() |
![]() |
![]() |
||
| LW26-125 | ![]() |
![]() |
![]() |
![]() |
|||
| LW26-160 | ![]() |
![]() |
![]() |
![]() |
|||
Technical parameters
| Description | LW26-10 | LW26-20 | LW26-25 | LW26-32 | |||||
| Rated thermal current lth | A | 10 | 20 | 25 | 32 | ||||
| Rated working voltage Ue | V | 240 | 440 | 240 | 440 | 240 | 440 | 240 | 440 |
| Rated working current le | |||||||||
| AC-21A AC-22A | A | 10 | 10 | 20 | 20 | 25 | 25 | 32 | 32 |
| AC-23A | 7.5 | 7.5 | 15 | 15 | 22 | 22 | 30 | 30 | |
| AC-2 | A | 7.5 | 7.5 | 15 | 15 | 22 | 22 | 30 | 30 |
| AC-3 | A | 5.5 | 5.5 | 11 | 11 | 15 | 15 | 22 | 22 |
| AC-4 | A | 1.75 | 1.75 | 3.5 | 3.5 | 6.5 | 6.5 | 11 | 11 |
| AC-15 | A | 2.5 | 1.5 | 5 | 4 | 8 | 5 | 14 | 6 |
| Power P | |||||||||
| AC-23A | kW | 1.8 | 3 | 3.7/2.5 | 7.5/3.7 | 5.5/3 | 11/5.5 | 7.5/4 | 15/7.5 |
| AC-2 | kW | 2.5 | 3.7 | 4 | 7.5 | 5.5 | 11 | 7.5 | 15 |
| AC-3 | kW | 1.5 | 2.2 | 3/2.2 | 5.5/3 | 4/3 | 7.5/3.7 | 5.5/4 | 11/5.5 |
| AC-4 | kW | 0.37 | 0.55 | 0.55/0.75 | 1.5/1.5 | 1.5/1.1 | 3/2.2 | 2.7/4 | 5.5/3 |
| Description | LW26-63 | LW26-125 | LW26-160 | ||||
| Rated thermal current lth | A | 63 | 125 | 160 | |||
| Rated, working voltage Ue, | V | 240 | 440 | 240 | 440 | 240 | 440 |
| Rated working current le | |||||||
| AC-21A AC-22A | A | 63 | 63 | 100 | 100 | 150 | 150 |
| AC-23A | A | 57 | 57 | 90 | 90 | 135 | 135 |
| AC-2 | A | 57 | 57 | 90 | 90 | 135 | 135 |
| AC-3 | A | 36 | 36 | 75 | 75 | 95 | 95 |
| AC-4 | A | 15 | 15 | 30 | 30 | 95 | 95 |
| AC-15 | A | ||||||
| Power P | |||||||
| AC-23A | kW | 15/10 | 30/18.5 | 30/15 | 45/22 | 37/22 | 75/37 |
| AC-2 | kW | 18.5 | 30 | 30 | 45 | 37 | 55 |
| AC-3 | kW | 11/6 | 18.5/11 | 15/7.5 | 30/13 | 22/11 | 37/18.5 |
| AC-4 | kW | 5.5/2.4 | 7.5/4 | 6/3 | 12/5.5 | 10/4 | 15/7.5 |
Re: Neutral;
Re: The power under AC-23A AC-3 AC-4 are in three phase three pole, and the divider represents the power under single phase two pole.
Mechanical life
- Mechanical life without load: 60x104times, operation frequency is 120 times/h;
- Mechanical life with load: 20x104times under AC-15, 6x104times under DC-13, operation frequency is 300 times/h.
Order procedures
In order to avoid any mistake during the order, customers should follow the right procedure’
The following information should be supplied:
- Contact diagram, we have published«Contact diagram for LW5D series rotary switches», the diagram applied for LW5D could applied to LW26 series as well. And we have selected sime typical diagrams in this catalog;
- Type of escutcheon plate;
- Type of handle;
- Character code and code of degree of rotation;
- Rated current;
- Quantity.
If you would like a quotation or further information on this product, please fill in the form below and we will reply to you within 1 working day. |
Related Products: |
About Us | Products | New Products | Download | Offer Board | Certificate | Contact Us
Copyright 2013 © GREEGOO Electric Co.,Ltd. All Rights Reserved. E-mail:Peter@greegoo.com
Add: No.6 Floor,Jinye Mansion, Lvzhuang, Liushi, Yueqing, Zhejiang, 325604 P.R. China Tel: +86-577-62776000 Mob: +86-159 5877 6000 Fax: +86-4008875666 Ext 088150