3 phase SCR power regulator HGW8 advanced digital type

Home Products SCR Power ControllerThyristor Power Controller (SCR Power Regulator)3 phase SCR power regulator HGW8 advanced digital type

3 phase SCR power regulator HGW8 advanced digital type
3 phase SCR power regulator HGW8 advanced digital type
3 phase SCR power regulator HGW8 advanced digital type
3 phase SCR power regulator HGW8 advanced digital type
3 phase SCR power regulator HGW8 advanced digital type
3 phase SCR power regulator HGW8 advanced digital type
Product details

3 phase SCR power regulator HGW8 advanced digital type

HGW8 Series Three-Phase full functional SCR Power Regulator

Product Features

◎ Full-function, fully intelligent SCR power regulator, supporting phase-through, constant current, constant voltage, constant power, zero-crossing, phase zero-crossing control with direct switching.

◎ Multiple setpoint mode options: analog, digital, communication setting, or direct keyboard setting.

◎ Intelligent protection functions, including phase loss, overtemperature, overcurrent, load wire break, load imbalance, and power frequency fault protection.

◎ Excellent output linearity. Precisely controlled by the microcontroller for duty cycle, with real-time display of load current, voltage, and power for monitoring the regulator's working status at any time.

◎ MODBUS RTU communication function, enabling networked control with HMI, PLC, etc., for remote monitoring.

◎ Suitable for various load types, such as resistive loads, silicon carbide rod loads, transformer loads, silicon molybdenum rod loads, with loads connectable to neutral wire.

◎ Up to two analog input channels, with direct switching between current and voltage signals.

◎ Parameter saving function after on-site debugging, allowing customization of specific parameter settings.

◎ One-key restore to factory defaults function, restoring to factory values or specific parameter settings to avoid faults caused by unauthorized on-site parameter modifications.

◎ Dual-row digital display, with customizable content on the upper and lower rows; the lower row can directly switch via keys to display input, output, voltage, current, power.

◎ Detachable display panel, installable on the control cabinet panel for direct monitoring of working status.

◎ Load current coverage from 30A to 450A, suitable for various heating power applications.

◎ No deformation after long-term use.

◎ Precision CNC-formed aluminum body, sturdy and durable, no deformation after long-term use, no loosening.

◎ All series come standard with high-speed DC fans or dual ball-bearing axial fans, long lifespan, fast heat dissipation, safe and reliable.

Technial Parameters
Input Main Circuit Power Three-phase AC 110-500V, 45-65Hz
Control Power 220V, 50Hz/60Hz
Output Output Voltage 0~98% of main circuit input voltage
Output Current 30A-800A
Applicable Loads Resistive Load/Inductive Load Nickel-chromium, iron-chromium-aluminum, far-infrared heating elements, silicon-aluminum rods, silicon-carbon rods, salt bath furnaces, power frequency induction furnaces, quenching furnaces, molten glass, rectifying transformers, power regulators (pure inductive coils), primary side of electric furnace transformers, stepless smooth adjustment of voltage, current, power, Primary and secondary sides of transformers
Main Features High-Precision AD Conversion 12-bit AD
Control Accuracy Better than 0.05%
Acquisition Resolution Higher than 0.025%
Closed-Loop Control Modes Open-loop, constant current, constant voltage, constant power (freely selectable)
Trigger Modes Zero-crossing, phase-shift, zero-crossing phase-shift (freely selectable)
Setpoint Signal Analog setpoint, keyboard digital setpoint, communication setpoint (freely selectable)
Analog Input Interface 2 programmable analog input channels: DC 0~20mA, DC 0~10V/DC 0~5V
Communication Interface RS485, Modbus RTU standard communication protocol
Soft Start, Soft Stop 0~120s
Protection Functions Frequency Fault Protection when power frequency is out of range
Power Supply Fault Protection when main circuit power fails
Overheat Protection Protection when thyristor temperature >85°C
Overcurrent Protection Protection when output current ≥ set multiple
Phase Loss Protection Protection when main circuit input power has phase loss
Load Wire Break Protection when load current < threshold current setting
Operating Environment Usage Location Indoor, no direct sunlight, no dust, corrosive gases, flammable gases, oil mist, water vapor, dripping water, or salt
Altitude Below 1000m; derate for use above 1000m
Ambient Temperature -10°C to 40°C (derate for use between 40°C and 50°C)
Humidity Less than 95% RH, no condensation
Vibration Less than 5.9m/s² (0.6g)
Model explanation
Part Numbers *1-*2-*3-*4-*5 e.g. HGW8-4-4-040-P
       
  Description Code Value
*1 Design Code HGW8  
*2 Phase 4 Three phase
*3 Main Power Supply 2 110-220V
    4 330-440V
*4 Rated Current 030 30A
    040 40A
    050 50A
    060 60A
    ... ...
    800 800A
*5 Control mode setting P Phase constant voltage current limiting
    C Phase constant current
    CV Phase constant power
    Z Cycle zero-crossing power regulation
    ZV Fixed cycle zero crossing power regulation
Specification
Model Rated
current
load(KW) Product
size (mm)
Mount
 size(mm)
Weight
(kg)
Screw Torque Cooling method
    220V 380V L W H L W        
HGW8-4-4-030-P 30A 9.5 16.5 335 164 213 316 104 10 M8 40kgfcm Forced air cooling
HGW8-4-4-040-P 40A 12.5 20 335 164 213 316 104 10 M8 40kgfcm Forced air cooling
HGW8-4-4-050-P 50A 15.5 27 335 164 213 316 104 10 M8 50kgfcm Forced air cooling
HGW8-4-4-060-P 60A 19 33 335 164 213 316 104 10 M8 50kgfcm Forced air cooling
HGW8-4-4-075-P 75A 23.5 41 335 164 213 316 104 10 M8 70kgfcm Forced air cooling
HGW8-4-4-080-P 80A 25.5 44 335 164 213 316 104 10 M8 70kgfcm Forced air cooling
HGW8-4-4-090-P 90A 28.5 49 335 164 213 316 104 10 M8 85kgfcm Forced air cooling
HGW8-4-4-100-P 100A 32 55 335 164 213 316 104 10 M8 85kgfcm Forced air cooling
HGW8-4-4-125-P 125A 40 68.5 335 164 213 316 104 10 M8 95kgfcm Forced air cooling
HGW8-4-4-150-P 150A 45 75 335 164 213 316 104 11 M8 170kgfcm Forced air cooling
HGW8-4-4-175-P 175A 53 88 335 164 213 316 104 11 M8 170kgfcm Forced air cooling
HGW8-4-4-200-P 200A 58 100 420 244 236 401 160 13 M10 220kgfcm Forced air cooling
HGW8-4-4-250-P 250A 73 125 420 244 236 401 160 13 M10 220kgfcm Forced air cooling
HGW8-4-4-300-P 300A 87 150 435 263 248 416 160 15 M10 250kgfcm Forced air cooling
HGW8-4-4-350-P 350A 100 177 435 263 248 416 160 18 M10 250kgfcm Forced air cooling
HGW8-4-4-400-P 400A 115 200 435 263 290 416 160 22 M10 250kgfcm Forced air cooling
HGW8-4-4-450-P 450A 130 220 435 263 290 416 160 25 M10 250kgfcm Forced air cooling
HGW8-4-4-500-P 500A 145 250 435 263 290 416 160 25 M10 250kgfcm Forced air cooling
HGW8-4-4-600-P 600A 175 300 525 388 330 495*3 140*2 37 M12 300kgfcm Forced air cooling
HGW8-4-4-800-P 800A 235 410 525 388 330 495*3 140*2 37 M12 300kgfcm Forced air cooling
Panel Function

Intelligent sCR controller

Wiring

Wiring HGW8 SCR controller

Copyright © Greegoo Electric Co., Ltd.