SCR power regulator three phase digital HGW5 type

Home Products SCR Power ControllerThyristor Power Controller (SCR Power Regulator)SCR power regulator three phase digital HGW5 type

SCR power regulator three phase digital HGW5 type
SCR power regulator three phase digital HGW5 type
SCR power regulator three phase digital HGW5 type
SCR power regulator three phase digital HGW5 type
SCR power regulator three phase digital HGW5 type
SCR power regulator three phase digital HGW5 type
Product details

SCR power regulator three phase digital HGW5 type

Product Features
◎ Utilizes MCU embedded microcontroller control technology and PID closed-loop control for 100% linear output.
◎ Three-phase full-control 6-pulse output, compatible with transformer loads or loads with neutral wire connection.
◎ Dual-channel input signal design: 0~5V, 0~10V, 4~20mA, or potentiometer limit, with direct switching.
◎ Fast-acting fuse combined with electronic transformer for dual overcurrent protection.
◎ Digital display for input, output, current, voltage, power, with one-key switching.

Model explaination
Part Numbers *1-*2-*3-*4-*5 e.g. HGW5-4-4-040-P
       
  Description Code Value
*1 Design Code HGW5  
*2 Phase 4 Three phase
*3 Main Power Supply 2 110-220V
    4 380-440V
*4 Rated Current 030 30A
    040 40A
    050 50A
    060 60A
    ... ...
    200 200A
*5 Control mode setting Z Zero positin adjustment
    P Open-loop phase control
    C Constant current control
Part Numbers
Part Numbers Current  Load
Power
(KW)
Appearance
Dimensions
(mm)
     Fixed
Dimensions
     (mm)
Weight
(kg)
Screw and Torque: Cooling Method Housing
220V 380V Length Width Height Length Width
HGW5-4-4-030-P 30A 9.5  16.5  200  110  160  130  105  2.2  M6 40kgfcm Natural cooling Fig. 1
HGW5-4-4-040-P 40A 12.5  20  200  110  160  130  105  2.5  M6 40kgfcm Natural cooling
HGW5-4-4-030-PF 30A 9.5  16.5  225  110  170  130  105  2.2  M6 40kgfcm forced air
cooling
Fig. 2
HGW5-4-4-040-PF 40A 12.5  20  225  110  170  130  105  2.5  M6 40kgfcm forced air
cooling
HGW5-4-4-050-P 50A 15.5  27  250  140  195  162  135  3.5  M6 50kgfcm forced air
cooling
Fig. 3
HGW5-4-4-060-P 60A 19  33  250  140  195  162  135  3.5  M6 50kgfcm forced air
cooling
HGW5-4-4-075-P 75A 23.5  41  250  140  195  162  135  3.5  M6 70kgfcm forced air
cooling
HGW5-4-4-080-P 80A 25.5  44  250  140  195  162  135  3.5  M6 75kgfcm forced air
cooling
HGW5-4-4-090-P 90A 28.5  49  250  140  205  162  135  3.5  M6 85kgfcm forced air
cooling
Fig. 4
HGW5-4-4-100-P 100A 32  55  250  140  205  162  135  3.5  M6 85kgfcm forced air
cooling
HGW5-4-4-125-P 125A 40  68.5  290  140  205  202  135  4.4  M8 95kgfcm forced air
cooling
Fig. 5
HGW5-4-4-150-P 150A 45  75  340  140  205  252  135  5.5  M8 170kgfcm forced air
cooling
Fig. 6
HGW5-4-4-175-P 175A 53  88  390  140  205  302  135  M8 200kgfcm forced air
cooling
Fig. 7
HGW5-4-4-200-P 200A 60  100  370  185  225  273  170  13  M8 220kgfcm forced air
cooling
Fig. 8
Copyright © Greegoo Electric Co., Ltd.

WeChat

WhatsApp

GreegooChina@Gmail.com

Send an Enquiry

We value your privacy

We use cookies to enhance your browsing experience, serve personalized ads or content, and analyze our traffic. By clicking "Accept All", you consent to our use of cookies.

Consent Preferences

Consent Preferences