PID Temperature Controller C900 Series
Home Products SCR Power ControllerTemperature ControllerPID Temperature Controller C900 Series
PID Temperature Controller C900 Series
Product Features
Uses a three-color LCD display, with clear and bright colors, making the display more beautiful;
Uses a plug-in spring terminal design, convenient for subsequent maintenance and replacement;
The CPU uses Japan's Renesas latest 32-bit industrial-grade chip, and Renesas chips are widely used in high-reliability occasions, such as automotive electronics;
Universal input, supports various thermocouples and thermal resistances, and also supports linear signals such as 4~20mA, 0~10V input;
Re-optimized PID control algorithm, and equipped with unique anti-overshoot PID control, with excellent effects on high-lag control objects such as electric furnaces;
Can be configured with 50 program segments, which can be divided into one group or five groups of curves according to process requirements;
RS-485 communication interface, supports MODBUS RTU communication protocol, and can be configured for master-slave communication;
Multiple output types, can select no-feedback proportional motor output, three-phase zero-crossing thyristor trigger output, single-phase, three-phase phase-shift thyristor trigger output.
| 1* Control | Code |
| Fixed Control | C |
| Programmable control | PC |
| 2* Mount | |
| DIN48x96 | 800 |
| DIN96x96 | 900 |
| 3* Output | |
| No output | 0 |
| Relay ouput | 1 |
| SSR ouput | 2 |
| 4-20mA output | 3 |
| 0-10V output | 4 |
| Three - phase zero | 6 |
| Proportional Motor without Feedback | 7 |
| Single - phase Phase Trigger | 8 |
| Three - phase | 9 |
| 4* Second Group Output | |
| No output | 0 |
| Relay ouput | 1 |
| SSR ouput | 2 |
| 4-20mA output | 3 |
| 0-10V output | 4 |
| 5* Alarm | |
| No alarm output | 0 |
| 1 alarm output | 1 |
| 2 alarm output | 2 |
| 6* Transmission Output | |
| No Transmission | 0 |
| PV 4-20mA Transmission | 1 |
| SV 4-20mA Transmission | 2 |
| 7* Auxiliary Power Supply | |
| No | 0 |
| 24V Auxiliary Power Supply | 1 |
| 8* Communication | |
| No | 0 |
| TTL Master - Slave Control | 3 |
| RS485 MODBUS | B |
| 9* Input signal | |
| Thermocouple | 1 |
| Thermoresistance (RTD) | 2 |
| Linear signal | 3 |
| 10* Main power supply | |
| 85~265V | A |
Tips
(1) For input signals: thermocouples and Thermoresistance can be switched freely; linear signals are factory-set and cannot be changed to other types.
(2) For master-slave control meters: the master meter is the programmable meter (PC) with TTL master-slave control selected for communication; the slave meter is the fixed-value meter (C), with TTL master-slave control also selected for communication. Example: master meter model – PC900-301003; slave meter model – C900-301003.
(3) Example: a meter with size 96×96 delivers main output as SSR output, second-group output as relay output, 1 alarm output, no transmission, MODBUS communication, and K-type thermocouple input signal. So the selected model is C900-21100B-1-A.
Need more information?