4-20mA, 0-10Vdc or 10kΩ control relay for dc load 100/200/600/1200V 60A to 500A built-in Freewheeling Diode for Inductive Load

">

DC to DC Solid State Control Relays built-in Freewheeling Diode

Home Products Solid State Relay (DC to DC)DC solid state relay for special purposeDC to DC Solid State Control Relays built-in Freewheeling Diode

100VDC

DC to DC Solid State Control Relays built-in Freewheeling Diode

Part Numbers Max.Current Max. Voltage Control Signal Casing
GZR-60100A 60A 100VDC 4-20mA J-8
GZR-80100A 80A 100VDC 4-20mA J-8
GZR-100100A 100A 100VDC 4-20mA J-8
GZR-120100A 120A 100VDC 4-20mA J-8
GZR-150100A 150A 100VDC 4-20mA J-8
GZR-200100A 200A 100VDC 4-20mA J-8
GZR-300100A 300A 100VDC 4-20mA J-8
GZR-400100A 400A 100VDC 4-20mA J-8
GZR-500100A 500A 100VDC 4-20mA J-8
GZR-60100V 60A 100VDC 0-10V J-8
GZR-80100V 80A 100VDC 0-10V J-8
GZR-100100V 100A 100VDC 0-10V J-8
GZR-120100V 120A 100VDC 0-10V J-8
GZR-150100V 150A 100VDC 0-10V J-8
GZR-200100V 200A 100VDC 0-10V J-8
GZR-300100V 300A 100VDC 0-10V J-8
GZR-400100V 400A 100VDC 0-10V J-8
GZR-500100V 500A 100VDC 0-10V J-8
GZR-60100P 60A 100VDC Pot 10 kΩ J-8
GZR-80100P 80A 100VDC Pot 10 kΩ J-8
GZR-100100P 100A 100VDC Pot 10 kΩ J-8
GZR-120100P 120A 100VDC Pot 10 kΩ J-8
GZR-150100P 150A 100VDC Pot 10 kΩ J-8
GZR-200100P 200A 100VDC Pot 10 kΩ J-8
GZR-300100P 300A 100VDC Pot 10 kΩ J-8
GZR-400100P 400A 100VDC Pot 10 kΩ J-8
GZR-500100P 500A 100VDC Pot 10 kΩ J-8
200VDC
Part Numbers Max.Current Max. Voltage Control Signal Casing
GZR-60200A 60A 200VDC 4-20mA J-8
GZR-80200A 80A 200VDC 4-20mA J-8
GZR-100200A 100A 200VDC 4-20mA J-8
GZR-120200A 120A 200VDC 4-20mA J-8
GZR-150200A 150A 200VDC 4-20mA J-8
GZR-200200A 200A 200VDC 4-20mA J-8
GZR-300200A 300A 200VDC 4-20mA J-8
GZR-400200A 400A 200VDC 4-20mA J-8
GZR-500200A 500A 200VDC 4-20mA J-8
GZR-60200V 60A 200VDC 0-10V J-8
GZR-80200V 80A 200VDC 0-10V J-8
GZR-100200V 100A 200VDC 0-10V J-8
GZR-120200V 120A 200VDC 0-10V J-8
GZR-150200V 150A 200VDC 0-10V J-8
GZR-200200V 200A 200VDC 0-10V J-8
GZR-300200V 300A 200VDC 0-10V J-8
GZR-400200V 400A 200VDC 0-10V J-8
GZR-500200V 500A 200VDC 0-10V J-8
GZR-60200P 60A 200VDC Pot 10 kΩ J-8
GZR-80200P 80A 200VDC Pot 10 kΩ J-8
GZR-100200P 100A 200VDC Pot 10 kΩ J-8
GZR-120200P 120A 200VDC Pot 10 kΩ J-8
GZR-150200P 150A 200VDC Pot 10 kΩ J-8
GZR-200200P 200A 200VDC Pot 10 kΩ J-8
GZR-300200P 300A 200VDC Pot 10 kΩ J-8
GZR-400200P 400A 200VDC Pot 10 kΩ J-8
GZR-500200P 500A 200VDC Pot 10 kΩ J-8
600VDC
Part Numbers Max.Current Max. Voltage Control Signal Casing
GZR-60600A 60A 600VDC 4-20mA J-8
GZR-80600A 80A 600VDC 4-20mA J-8
GZR-100600A 100A 600VDC 4-20mA J-8
GZR-120600A 120A 600VDC 4-20mA J-8
GZR-150600A 150A 600VDC 4-20mA J-8
GZR-200600A 200A 600VDC 4-20mA J-8
GZR-300600A 300A 600VDC 4-20mA J-8
GZR-400600A 400A 600VDC 4-20mA J-8
GZR-500600A 500A 600VDC 4-20mA J-8
GZR-60600V 60A 600VDC 0-10V J-8
GZR-80600V 80A 600VDC 0-10V J-8
GZR-100600V 100A 600VDC 0-10V J-8
GZR-120600V 120A 600VDC 0-10V J-8
GZR-150600V 150A 600VDC 0-10V J-8
GZR-200600V 200A 600VDC 0-10V J-8
GZR-300600V 300A 600VDC 0-10V J-8
GZR-400600V 400A 600VDC 0-10V J-8
GZR-500600V 500A 600VDC 0-10V J-8
GZR-60600P 60A 600VDC Pot 10 kΩ J-8
GZR-80600P 80A 600VDC Pot 10 kΩ J-8
GZR-100600P 100A 600VDC Pot 10 kΩ J-8
GZR-120600P 120A 600VDC Pot 10 kΩ J-8
GZR-150600P 150A 600VDC Pot 10 kΩ J-8
GZR-200600P 200A 600VDC Pot 10 kΩ J-8
GZR-300600P 300A 600VDC Pot 10 kΩ J-8
GZR-400600P 400A 600VDC Pot 10 kΩ J-8
GZR-500600P 500A 600VDC Pot 10 kΩ J-8
1200VDC
Part Numbers Max.Current Max. Voltage Control Signal Casing
GZR-601200A 60A 1200VDC 4-20mA J-8
GZR-801200A 80A 1200VDC 4-20mA J-8
GZR-1001200A 100A 1200VDC 4-20mA J-8
GZR-1201200A 120A 1200VDC 4-20mA J-8
GZR-1501200A 150A 1200VDC 4-20mA J-8
GZR-2001200A 200A 1200VDC 4-20mA J-8
GZR-3001200A 300A 1200VDC 4-20mA J-8
GZR-4001200A 400A 1200VDC 4-20mA J-8
GZR-5001200A 500A 1200VDC 4-20mA J-8
GZR-601200V 60A 1200VDC 0-10V J-8
GZR-801200V 80A 1200VDC 0-10V J-8
GZR-1001200V 100A 1200VDC 0-10V J-8
GZR-1201200V 120A 1200VDC 0-10V J-8
GZR-1501200V 150A 1200VDC 0-10V J-8
GZR-2001200V 200A 1200VDC 0-10V J-8
GZR-3001200V 300A 1200VDC 0-10V J-8
GZR-4001200V 400A 1200VDC 0-10V J-8
GZR-5001200V 500A 1200VDC 0-10V J-8
GZR-601200P 60A 1200VDC Pot 10 kΩ J-8
GZR-801200P 80A 1200VDC Pot 10 kΩ J-8
GZR-1001200P 100A 1200VDC Pot 10 kΩ J-8
GZR-1201200P 120A 1200VDC Pot 10 kΩ J-8
GZR-1501200P 150A 1200VDC Pot 10 kΩ J-8
GZR-2001200P 200A 1200VDC Pot 10 kΩ J-8
GZR-3001200P 300A 1200VDC Pot 10 kΩ J-8
GZR-4001200P 400A 1200VDC Pot 10 kΩ J-8
GZR-5001200P 500A 1200VDC Pot 10 kΩ J-8
Circuit Drawing

build in freewheeling diode control relay for inductive load

Dimensions

J-8 casing outline dimensions

Selection guidelines

Selection guidelines:

When selecting our product, it is important to consider the nature of the load and leave appropriate margins for current and voltage levels. For resistive loads, choose the current based on 2-4 times the load current and the voltage based on 2-3 times the load voltage. For inductive or capacitive loads, select the current based on 4-8 times the load current and the voltage based on 4-5 times the load voltage.

To ensure optimal performance, take into account the relationship between the load current and ambient temperature. If the ambient temperature is high or the heat dissipation conditions are poor, it is recommended to increase the current capacity. To prevent short circuits in the load circuit during use, it is essential to include a fast circuit breaker or a fast fuse in the load circuit.

When dealing with inductive loads, it is crucial to include a freewheeling diode in parallel with the load or a voltage-dependent resistor and RC absorption circuit at the output end to prevent damage to the transistor from over-voltage. The voltage-dependent resistor (MOV) should be selected according to 1-2 times the power supply voltage, and the RC value should be selected according to the load power.

During installation, make sure that the contact surface between the heat sink and the product is flat and smooth. Apply a layer of thermal grease to its surface to optimize heat dissipation. Finally, tighten the screw with a flat washer and a spring washer symmetrically to secure it in place. We hope these guidelines help you to make the best use of our product.

Copyright © Greegoo Electric Co., Ltd.

Chat through WhatsApp Now

Chat through Wechat Now

Send an Enquiry

We value your privacy

We use cookies to enhance your browsing experience, serve personalized ads or content, and analyze our traffic. By clicking "Accept All", you consent to our use of cookies.

Consent Preferences

Consent Preferences